The time cost of physiologically ineffective intravenous fluids in the emergency department: an observational pilot study employing wearable Doppler ultrasound

Abstract

Background

Little data exist on the time spent by emergency department (ED) personnel providing intravenous (IV) fluid to ‘responsive’ versus ‘unresponsive’ patients.

Methods

A prospective, convenience sample of adult ED patients was studied; patients were enrolled if preload expansion was indicated for any reason. Using a novel, wireless, wearable ultrasound, carotid artery Doppler was obtained before and throughout a preload challenge (PC) prior to each bag of ordered IV fluid. The treating clinician was blinded to the results of the ultrasound. IV fluid was deemed ‘effective’ or ‘ineffective’ based on the greatest change in carotid artery corrected flow time (ccFT) during the PC. The duration, in minutes, of each bag of IV fluid administered was recorded.

Results

53 patients were recruited and 2 excluded for Doppler artifact. There were 86 total PCs included in the investigation comprising 81.7 L of administered IV fluid. 19,667 carotid Doppler cardiac cycles were analyzed. Using ccFT ≥  + 7 ms to discriminate ‘physiologically effective’ from ‘ineffective’ IV fluid, we observed that 54 PCs (63%) were ‘effective’, comprising 51.7 L of IV fluid, whereas, 32 (37%) were ‘ineffective’ comprising 30 L of IV fluid. 29.75 total hours across all 51 patients were spent in the ED providing IV fluids categorized as ‘ineffective.’

Conclusions

We report the largest-known carotid artery Doppler analysis (i.e., roughly 20,000 cardiac cycles) in ED patients requiring IV fluid expansion. A clinically significant amount of time was spent providing physiologically ineffective IV fluid. This may represent an avenue to improve ED care efficiency.

Introduction

As a concept, fluid responsiveness has grown and evolved over the last 20 years [1,2,3]. At its core is the notion that intravenous (IV) fluid has an intended effect, that is, to increase stroke volume (SV) [4, 5]. This cause-and-effect relationship between cardiac input (i.e., preload, IV fluids) and SV is described by the ‘Starling’, or ‘cardiac function’, curve [6, 7]. Critically, during acute illness many patients flatten their cardiac function curve such that augmenting preload with IV fluid does not have the intended effect of improving SV [8, 9]. Therefore, without measuring blood flow change in response to IV fluid, the desired outcome of administering preload is uncertain.

Despite the aforementioned physiological rationale for individualizing IV fluid therapy, there is little and conflicting data supporting better outcome with this paradigm, especially in the emergency department (ED) [10]. For example, a meta-analysis of goal-directed fluid therapy in the operating room revealed that flow-guided resuscitation improved patient outcomes [11], though when restricted to septic, critically ill patients, no clear differences were observed [12]. Two recent evaluations of septic patients in the intensive care unit (ICU) reported that flow-guided IV fluid resuscitation diminished fluid administration, complications secondary to overload (e.g., mechanical ventilation time, renal replacement therapy) and cost as compared to standard care [13, 14]. These findings led some authorities to reframe testing for ‘fluid responsiveness’ as, instead, evaluating for a ‘fluid refractory’ state [15]. Conversely, two trials in septic ED patients found that patients managed by ‘fluid responsiveness’ assessments received more IV fluids without any patient-centered improvement [16, 17]. Importantly, however, in both ED studies the resuscitation protocols encouraged IV fluids until fluid responsiveness disappeared—an inappropriate approach [3].

In addition to patient-centered outcomes, another perspective on IV fluid administration is that of resource utilization in the ED. Arguably, unnecessary tests and therapies hinder ED throughput and the provision of physiologically ineffective IV fluid could be considered in this regard. In both ED studies above, there were relatively high initial fluid unresponsive rates (i.e., 21% [16] and 53% [17]). Similar fractions were noted early in the FRESH [13] and in ANDROMEDA-SHOCK [18] trials. Moreover, in the critically ill cohort of ANDROMEDA-SHOCK, withholding IV fluid in unresponsive patients did not cause harm [9]. Therefore, early detection of fluid unresponsiveness (i.e., a ‘fluid refractory’ patient) in the ED could save both patients from an arguably ineffective medical therapy and providers from the time spent carrying out an unneeded intervention.

With the above, the STudying the Over-Prescription of IV FLuids via an ObservatiOnal Doppler INvestiGation (STOP-FLOODING) was designed and completed as a pilot study in a community ED. Our primary goal was to quantify the burden of fluid unresponsiveness early in ED care; our secondary goal was to calculate the time spent providing physiologically ineffective IV fluid. These objectives were accomplished using a novel, wireless, wearable Doppler ultrasound system [19]. We have previously shown a strong, linear correlation between the change in the common carotid artery corrected flow time (ccFT) and stroke volume (SV) using this device [20, 21]. Furthermore, Barjaktarevic and colleagues found that ccFT could accurately detect SV in undifferentiated shock [22]. Therefore, to accomplish our primary and secondary goals, we measured the ccFT during a preload challenge prior to each bag of IV fluid and with the treating clinician blind to the results of the Doppler ultrasound.

Materials and methods

A prospective, convenience sample of adult patients presenting to a single community ED in Peoria, Illinois, U.S.A. was studied. The patients were enrolled between February and April 2022. The study was performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments. Patients or their legal representative provided written, informed consent and the study was approved by the Peoria Institutional Review Board (# 1697834-5).

Adult patients were enrolled if the treating clinician determined that IV fluid expansion would be beneficial for any indication. Patients were excluded if they were not at least 18 years old, if they did not provide informed consent, if they were unable to cooperate with a Doppler ultrasound assessment of the carotid artery (e.g., delirium, confusion, excessive phonation, etc.) or if there were anatomical contraindications precluding assessment of at least one carotid artery (e.g., known bilateral carotid stenoses of at least 70%, bilateral internal jugular central lines, c-spine collar, etc.).

Prior to each IV fluid bag of at least 500 mL, 30–60 s of resting carotid Doppler was recorded using a wireless, wearable Doppler ultrasound (Flosonics Medical, Sudbury, Ontario, Canada). The wearable Doppler system automatically traces the maximum velocity envelope of the carotid artery Doppler pulse and calculates the corrected flow time (ccFT) by the equation of Wodey [20,21,22,23] (Fig. 1). Immediately thereafter, a preload challenge (PC) was performed. At the discretion of the treating clinician, the PC could be either a rapid fluid challenge (RFC) or a passive leg raise (PLR). The treating clinician was blinded to all measures from the wearable Doppler ultrasound; continuous carotid Doppler was recorded throughout the entirety of the PC only.

Fig. 1
figure 1

The wearable Doppler ultrasound and its interface. A The device on a healthy volunteer. B Carotid Doppler spectra showing calculation of carotid corrected flow time (ccFT) by the equation of Wodey. Velocity is on y-axis in centimeters per second (cm/s) and time on x-axis in seconds (s); heart rate (HR) is calculated from cycle length. C Example of a preload challenge shown on the graphical user interface of the wearable Doppler. Each green bar represents the ccFT of a single cardiac cycle; the y-axis is ccFT in milliseconds and the x-axis is time in seconds

The RFC consisted of the first 250 mL of the fluid bag delivered at a rate of at least 100 mL/min [24,25,26]. This infusion rate was accomplished based on the size of the intravenous catheter through which the fluid was delivered [27]. If pressure was required to achieve an adequate infusion rate, either a standard pressure bag or the LifeFlow device (410 Medical, Durham, North Carolina, U.S.A.) was employed, at the discretion of the treating clinician. The PLR consisted of moving the patient from semi-recumbent baseline to supine with the legs passively raised for at least 90 s, per expert recommendation [28, 29].

The Doppler spectra were analyzed for the absolute and % ccFT. The number of cardiac cycles averaged before and during preload augmentation was dictated by the coefficient of variation of the ccFT to ensure change could be detected with statistical confidence [30]. The assessment windows showing the largest change between baseline and preload augmentation were considered for analysis.

After completing the PC by either RFC or PLR, IV fluid was infused at the discretion of the treating clinician. For example, if a patient was ordered for 1.5 Liters (L) of IV fluid, 2 PCs were performed, 1 prior to the 1-L bag and 1 prior to the 500-mL bag. If the PCs were accomplished by RFC, the first 250 mL of each bag were infused into the patient at 100 mL/min with carotid Doppler recording (i.e., the PC) and the remainder of each bag continued at any rate with no Doppler recording (i.e., after the PC). If instead, PLR was chosen as the PC, then the patient would have also received 2 PLRs (1 prior to the 1-L bag and 1 prior to the 500-mL bag) with carotid Doppler recording only during the PLR (i.e., the PC) but not during fluid administration (i.e., after the PC).

Prior to and immediately after each PC, vital signs were documented, as well, the total time required for each bag of IV fluid was recorded. The total time for each bag began with the onset of the RFC (or the beginning of the infusion after the PLR) and ended when the entire bag of fluid was administered. Only IV fluid administered for resuscitation was considered in this analysis (i.e., fluid given by gravity or maximal pump infusion rate), maintenance fluids were not included.

The primary outcome measure was the fraction of fluid unresponsive patients early in ED care and, therefore, total volume of ‘ineffective’ IV fluid (IVFineff) administered to these patients. The secondary outcome measure was the time spent in the ED delivering IVFineff, per patient. IVFineff was defined as any volume of fluid administered for which the antecedent PC disclosed an absolute ccFT of less than + 7 ms. This was the optimal threshold for detecting a 10% SV as identified by Barjaktarevic and colleagues [22].

Additional analyses were the same as above, however, different thresholds of ccFT were used to define IVFineff. For instance, in the investigation by Barjaktarevic et al. a + 4 ms absolute ccFT was as accurate as + 7 ms, however, + 4 ms traded improved sensitivity for specificity. Further, in previous research on healthy volunteers performing a simple preload modifying maneuver [20] or undergoing moderate-to-severe central hypovolemia and simulated blood transfusion [21, 31], we found that 2% and 4% ccFT, respectively, best identified a 10% SV. Hence, we studied these thresholds as well.

As exploratory analyses, the change in heart rate (HR), in beats per minute (bpm), and mean arterial pressure (MAP), in millimeters of mercury (mmHg) as calculated from immediately before to immediately after the preload challenge were compared via a 2-tailed Student’s t-test between ‘effective’ and ‘ineffective’ preload challenges as determined for the different ccFT thresholds listed above, but only if determined to be normally distributed by Kolmogorov–Smirnov testing. We tested the null hypothesis that there is no difference between the HR (or MAP) between ineffective and effective preload challenges. Lastly, using Chi-squared we tested the relationship between ‘effective’ and ‘ineffective’ preload challenges and the clinician’s use of an RFC or PLR.

Results

53 patients were enrolled for study and 2 were excluded because no usable Doppler spectra could be obtained. The clinical characteristics of the 51 patients included in this analysis are summarized in Table 1. Across the 51 patients, 94 PCs were performed and 8 PCs were excluded because there was no clear dicrotic notch discernable on the carotid spectrogram to calculate ccFT; therefore, 86 total PCs are included in this investigation comprising 19,667 carotid Doppler beats. 14% of patients were admitted to the ICU; 63% of patients were admitted to the general medical or surgical floor and 20% of patients were discharged from the ED. 17% had norepinephrine initiated in the emergency department and the 28-day re-admission and mortality rates for the 51 patients were 24% and 10%, respectively.

Table 1 Baseline patient characteristics

Of the 86 PCs, 77 (90%) were via RFC and, of these, 65 (84%) were achieved via the LifeFlow device. In total, 81.7 L of IV fluid were delivered to the 51 patients (i.e., a mean of 1.6 L/patient); the average infusion duration was 67 min/L, or 97.8 min per patient, on average. The distribution of these 81.7 L into ‘effective’ or ‘ineffective’ based upon different ccFT thresholds is shown in Fig. 2. In Table 2, we report the fraction of unresponsive patients on first assessment, during any assessment or on all assessments as determined by different, previously reported, optimal ccFT thresholds.

Fig. 2
figure 2

Distribution of effective and ineffective preload challenges based on ccFT thresholds determined by Barjaktarevic and colleagues

Table 2 The fraction of unresponsive patients and total time burden of ineffective fluids based on different ccFT thresholds

The relationship between change in HR (HR, in bpm) and change in MAP (MAP, in mmHg) before and after a PC for ‘effective’ and ‘ineffective’ assessments is shown in Table 3. Both HR and MAP were normal in distribution by Kolmogorov–Smirnov testing. There was no statistically significant change in HR or MAP between effective and ineffective PCs as defined by any threshold.

Table 3 The change in heart rate and mean arterial pressure between effective and ineffective preload challenges as determined by different ccFT thresholds

With respect to the interaction between ‘effective’ and ‘ineffective’ PCs and the clinician’s decision to employ a rapid fluid challenge or passive leg raise, we found there to be no statistically significant interaction by Chi-squared testing; however, only 9 of the 86 PCs were by PLR.

Discussion

In this pilot study conducted in a large, community ED, we enrolled patients requiring IV fluid administration based upon clinical examination. With respect to our primary goal, we observed a clinically significant fraction of fluid ‘unresponsive’ or ‘refractory’ [15] patients. This determination was based upon change in the carotid artery corrected flow time and was true whether a threshold with higher sensitivity (i.e., + 4 ms) or specificity (i.e., + 7 ms) was chosen [22]. A practical implication of these findings was measured in our secondary goal, that is, we observed a relatively large proportion of patients early in their care receiving physiologically ineffective IV fluids that consume valuable time in the ED. For instance, even with the + 4 ms threshold, our results indicate that for every 100 patients ordered IV fluid, approximately 28 h of ED care are spent on an intervention without its intended effect. As the 2021 operating expense of an ED with 100,000 annual visits ranges from $600–3000 per bed-hour (USD) [32], this represents $17,000 to $84,990 of hidden time cost; with the + 7 ms threshold, these totals approximately double for the same 100 patients.

As discussed above, the rates of fluid ‘unresponsiveness’ noted in this observational report are comparable to those observed by other investigators [10, 13, 16,17,18], however, our population was unselected, adult ED patients as compared to patients with sepsis and septic shock. Therefore, comparisons are not straightforward. For example, Kuan and colleagues used the PLR-induced change in bioreactance-measured stroke volume of at least 10% as the reference standard [16]. They observed a 28-day mortality rate of 9.8% and 21.3% of patients in their ED were unresponsive on first presentation. In our cohort, 75% of patients had infection-related hypoperfusion, the 28-day mortality rate was also 10% and, per the 4 ms ccFT threshold, we noted an initial 24% unresponsiveness rate, comparable to Kuan et al. [16]. As well, in the ANDROMEDA-SHOCK investigation, which used pulse pressure variation in sedated, ventilated patients and PLR with change in Doppler-derived stroke volume in spontaneously breathing patients, approximately one-quarter of initial assessments were unresponsive, though in a much sicker, septic population [18]. Leisman and colleagues retrospectively determined the clinical response to fluid therapy in a large cohort of septic ED patients [33]. Importantly, in their study, they qualified the response to IV fluids based upon a patient achieving normotension without vasoactive medications—perhaps better termed ‘baro-responsive’ given that ‘fluid responsive’ typically connotes blood flow [3]. Further, they identified six clinical risk factors to predict which patients would remain hypotensive following fluids. Nevertheless, even in those without any clinical risk factors, they observed that more than one-in-four hypotensive, septic patients did not normalize their blood pressure with fluids alone. We suspect that the great majority of these low-risk patients did not augment SV with preload and, therefore, could have been detected earlier in their ED course with flow-guided monitoring.

Lastly, and from more of a clinical-physiological perspective, we appreciate that the + 7 ms threshold has a lower sensitivity (i.e., 70%) than specificity (i.e., 96%), meaning that those marked as fluid unresponsive are more likely to be a false negative than those above this threshold are to be a false positive [22]. This is why we also considered the + 4 ms threshold which, as reported by Barjaktarevic and colleagues [22], reduces the false negative rate by roughly 13%, though raises the false positive rate by a similar amount. Based on these observations, we wonder if different thresholds could be applicable in different treatment environments. For example, in clinical scenarios where under-resuscitation is deemed more concerning (e.g., early ED septic shock in a young patient), a lower, ‘fluid liberal’, ccFT might be considered as a treatment threshold; whereas, in situations where over-resuscitation becomes more worrisome (e.g., later in ICU care in a patient with cardiovascular disease), a higher, ‘fluid conservative’, ccFT threshold might be employed to dichotomize fluid non-responders from responders. Future, prospective evaluations wherein these thresholds are used to guide management could resolve which is clinically superior.

The primary limitation of this study is that we did not directly measure SV as a reference standard for determining the physiological effect of IV fluid. It might be considered that the lack of change in heart rate and blood pressure between ‘effective’ and ‘ineffective’ preload challenges (Table 3) invalidates ccFT as a marker of SV. However, it has been known for decades that neither heart rate nor blood pressure can accurately gauge SV [2, 3, 34]. Furthermore, ccFT is a promising surrogate for % SV [35,36,37,38,39,40,41,42,43], even in the critically ill [22, 44], as mentioned in a recent systematic review [45]. Further, our data in healthy volunteers undergoing moderate-to-severe central hypovolemia, followed by simulated blood transfusion—induced by lower body negative pressure (LBNP) and release—demonstrated a strong, linear relationship between SV and ccFT [21, 31]. This LBNP analysis comprised approximately 50,000 cardiac cycles making it, to our knowledge, the largest known physiological comparison between SV and ccFT. Nevertheless, a recent ED study found that ccFT was unable to accurately detect a significant change in cardiac output [46]. As noted by the authors, this discrepancy may have been due to the skill-level of the sonographers performing the measurements. Further, we have observed clinically significant algorithm-lag between bioreactance SV and Doppler ultrasonography [47, 48] and that respiratory cycle-mediated ccFT variability requires averaging at least 6–7 cardiac cycles (and often more) before and after an intervention to detect change with statistical confidence [30]. Therefore, timing with the reference standard must be closely regarded and many more than 1–3 cardiac cycles should be recorded in the carotid artery.

Second, we did not restrict our inclusion criteria to patients in shock or a specific etiology of hypoperfusion. Therefore, applying the ccFT thresholds determined by Barjaktarevic and colleagues may not be physiologically appropriate given that their patient population was undifferentiated shock in the ICU [22]. Nevertheless, we applied various thresholds for detecting a 10% SV including from healthy volunteers performing a simple preload modifying maneuver [20] and those in an LBNP chamber [31] which may more closely approximate the spectrum of hemodynamic duress in the ED. Despite this, for all thresholds studied, we observed a clinically significant fraction of ED patients, early in their care, demonstrating a fluid ‘unresponsive’ or ‘refractory’ phenotype. The physiological implication of these observations is unclear, but given that withholding IV fluids in much sicker, unresponsive patients is without adverse effect [9], we postulate that refraining from IV fluids in the unresponsive patients observed in this general ED population would also have been unharmful. IV fluid in these unresponsive patients could represent an unnecessary therapy and additional time cost for ED providers that could be safely stopped.

Third, 2 patients and 8 preload challenges were excluded. In the 2 excluded patients, both had grossly atypical carotid Doppler morphology with no clear dicrotic notch. As these patients may have had undisclosed cardiovascular disease, it is possible that excluding them from our analysis could bias our results and diminish generalizability. Nevertheless, the average age and baseline characteristics of our patient population are expected given our relatively broad inclusion criteria within a community ED. Further, the non-selective, pragmatic, inclusion criteria could be considered beneficial given that it reflects typical IV bolus practice in the ED.

Finally, the total time burden of ineffective IV fluid was determined not just by the fraction of patients who received physiologically ineffective fluid, but also the rate at which the fluid was administered. We asked the treating clinicians not to deviate from their typical care which improves the external validity of our observational study. However, if each bag of fluid was administered as rapidly as the RFC, then the total time spent would have been less. The average duration of slightly over 1 h per litre reflects the common practice of running IV fluid at 999 mL/h based on maximal pump speed.

Conclusions

In conclusion, using both sensitive and specific ccFT thresholds, we observed a clinically significant fraction of fluid ‘unresponsive’ or ‘refractory’ patients early in their ED care. This could represent cryptic patient and time cost in the ED. Given that there is a movement to treat IV fluids akin to antibiotics (i.e., ‘fluid stewardship’ [49]), administering IV fluid to refractory patients would be comparable to treating an infection with antibiotics to which the offending micro-organism is resistant—a course of action that is unhelpful, time-consuming and worthy of practice improvement. Future investigation will better define the role of early, flow-guided care in the ED, especially with regard to patient population selection, decision support, outcome, but also ED provider time-utilization, throughput and care-cost. Towards these ends, a lightweight, wireless, wearable Doppler ultrasound may establish new areas of investigation and practice within the emergency department and intensive care unit.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

IV:

Intravenous

SV:

Stroke volume

ED:

Emergency department

ICU:

Intensive care unit

ccFT :

Change in the carotid artery corrected flow time

mL:

Milliliters

ccFT:

Carotid artery corrected flow time

PC:

Preload challenge

PLR:

Passive leg raise

L:

Liter

IVFineff :

Ineffective IV fluids

ms:

Milliseconds

SV :

Change in stroke volume

HR:

Heart rate

MAP:

Mean arterial pressure

mmHg:

Millimeters of mercury

HR :

Change in heart rate

MAP :

Change in mean arterial pressure

References

  1. Michard F, Teboul J-L. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care. 2000;4(5):282.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Michard F, Teboul J-L. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121(6):2000–8.

    Article  PubMed  Google Scholar 

  3. Monnet X, Shi R, Teboul J-L. Prediction of fluid responsiveness. What’s new? Ann Intensive Care. 2022;12(1):46.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Kenny J-ES, Barjaktarevic I. Letter to the Editor: Stroke volume is the key measure of fluid responsiveness. Crit Care. 2021;25(1):104.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Finfer S, Myburgh J, Bellomo R. Intravenous fluid therapy in critically ill adults. Nat Rev Nephrol. 2018;14(9):541–57.

    Article  PubMed  Google Scholar 

  6. Berlin DA, Bakker J. Starling curves and central venous pressure. Crit Care. 2015;19(1):55.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Kenny JES. Assessing fluid intolerance with Doppler ultrasonography: a physiological framework. Med Sci. 2022;10(1):12.

    Google Scholar 

  8. Messina A, Dell’Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, Saderi L, Sotgiu G, Antonelli M, Cecconi M. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019;23(1):264.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Kattan E, Ospina-Tascón GA, Teboul J-L, Castro R, Cecconi M, Ferri G, Bakker J, Hernández G, Investigators A-S. Systematic assessment of fluid responsiveness during early septic shock resuscitation: secondary analysis of the ANDROMEDA-SHOCK trial. Crit Care. 2020;24(1):23.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Elwan MH, Roshdy A, Elsharkawy EM, Eltahan SM, Coats TJ. The haemodynamic dilemma in emergency care: Is fluid responsiveness the answer? A systematic review. Scand J Trauma Resusc Emerg Med. 2017;25(1):25.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Bednarczyk JM, Fridfinnson JA, Kumar A, Blanchard L, Rabbani R, Bell D, Funk D, Turgeon AF, Abou-Setta AM, Zarychanski R. Incorporating dynamic assessment of fluid responsiveness into goal-directed therapy: a systematic review and meta-analysis. Crit Care Med. 2017;45(9):1538.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Ehrman RR, Gallien JZ, Smith RK, Akers KG, Malik AN, Harrison NE, Welch RD, Levy PD, Sherwin RL. Resuscitation guided by volume responsiveness does not reduce mortality in sepsis: a meta-analysis. Crit Care Explor. 2019;1(5): e0015.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Douglas IS, Alapat PM, Corl KA, Exline MC, Forni LG, Holder AL, Kaufman DA, Khan A, Levy MM, Martin GS. Fluid response evaluation in sepsis hypotension and shock: a randomized clinical trial. Chest. 2020;158(4):1431–45.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Latham HE, Bengtson CD, Satterwhite L, Stites M, Subramaniam DP, Chen GJ, Simpson SQ. Stroke volume guided resuscitation in severe sepsis and septic shock improves outcomes. J Crit Care. 2017;42:42–6.

    Article  PubMed  Google Scholar 

  15. Satterwhite L, Latham H. Fluid management in sepsis hypotension and septic shock: time to transition the conversation from fluid responsive to fluid refractory? Chest. 2020;158(4):1319–20.

    Article  PubMed  Google Scholar 

  16. Kuan WS, Ibrahim I, Leong BS, Jain S, Lu Q, Cheung YB, Mahadevan M. Emergency department management of sepsis patients: a randomized, goal-oriented, noninvasive sepsis trial. Ann Emerg Med. 2016;67(3):367-378.e363.

    Article  PubMed  Google Scholar 

  17. Hou PC, Filbin MR, Napoli A, Feldman J, Pang PS, Sankoff J, Lo BM, Dickey-White H, Birkhahn RH, Shapiro NI. Cardiac output monitoring managing intravenous therapy (COMMIT) to treat emergency department patients with sepsis. Shock. 2016;46(2):132–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. Hernández G, Ospina-Tascón GA, Damiani LP, Estenssoro E, Dubin A, Hurtado J, Friedman G, Castro R, Alegría L, Teboul J-L. Effect of a resuscitation strategy targeting peripheral perfusion status vs serum lactate levels on 28-day mortality among patients with septic shock: the ANDROMEDA-SHOCK randomized clinical trial. JAMA. 2019;321(7):654–64.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Kenny J-ÉS, Munding CE, Eibl JK, Eibl AM, Long BF, Boyes A, Yin J, Verrecchia P, Parrotta M, Gatzke R. A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery. Sci Rep. 2021;11(1):1–11.

    Article  Google Scholar 

  20. Kenny J-ÉS, Barjaktarevic I, Mackenzie DC, Eibl AM, Parrotta M, Long BF, Eibl JK. Diagnostic characteristics of 11 formulae for calculating corrected flow time as measured by a wearable Doppler patch. Intensive Care Med Exp. 2020;8(1):1–11.

    Article  Google Scholar 

  21. Kenny J-ÉS, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Yang Z, Eibl AM, Eibl JK, Kim C-H, Johnson BD. Carotid Doppler ultrasonography correlates with stroke volume in a human model of hypovolaemia and resuscitation: analysis of 48570 cardiac cycles. Br J Anaesth. 2021;127(2):e60–3.

    Article  PubMed  Google Scholar 

  22. Barjaktarevic I, Toppen WE, Hu S, Montoya EA, Ong S, Buhr R, David IJ, Wang T, Rezayat T, Chang SY. Ultrasound assessment of the change in carotid corrected flow time in fluid responsiveness in undifferentiated shock. Crit Care Med. 2018;11:1040–6.

    Article  Google Scholar 

  23. Wodey E, Carre F, Beneux X, Schaffuser A, Ecoffey C. Limits of corrected flow time to monitor hemodynamic status in children. J Clin Monit Comput. 2000;16(3):223–8.

    Article  CAS  PubMed  Google Scholar 

  24. Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, Zoric L, Suehs C, de La Coussaye JE, Molinari N, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology. 2011;115(3):541–7.

    Article  CAS  PubMed  Google Scholar 

  25. Wu Y, Zhou S, Zhou Z, Liu B. A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care. 2014;18(3):R108.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Barthélémy R, Kindermans M, Delval P, Collet M, Gaugain S, Cecconi M, Mebazaa A, Chousterman BG. Accuracy of cumulative volumes of fluid challenge to assess fluid responsiveness in critically ill patients with acute circulatory failure: a pharmacodynamic approach. Br J Anaesth. 2021. https://doi.org/10.1016/j.bja.2021.10.049.

    Article  PubMed  Google Scholar 

  27. Reddick AD, Ronald J, Morrison WG. Intravenous fluid resuscitation: was Poiseuille right? Emerg Med J. 2011;28(3):201–2.

    Article  PubMed  Google Scholar 

  28. Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul J-L. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34(5):1402–7.

    Article  PubMed  Google Scholar 

  29. Monnet X, Teboul J-L. Passive leg raising. Intensive Care Med. 2008;34(4):659–63.

    Article  PubMed  Google Scholar 

  30. Kenny JÉS, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Math ZYB, Eibl AM, Eibl JK, Kim CH, Johnson BD. Carotid Doppler measurement variability in functional hemodynamic monitoring: an analysis of 17,822 cardiac cycles. Crit Care Explor. 2021;3(6):e0439.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Kenny J-ÉS, Barjaktarevic I, Mackenzie DC, Elfarnawany M, Yang Z, Eibl AM, Eibl JK, Kim C-H, Johnson BD. Carotid artery velocity time integral and corrected flow time measured by a wearable Doppler ultrasound detect stroke volume rise from simulated hemorrhage to transfusion. BMC Res Notes. 2022;15(1):7.

    Article  PubMed  PubMed Central  Google Scholar 

  32. Phelan MP, Ramos C, Walker LE, Richland G, Reineks EZ. The hidden cost of hemolyzed blood samples in the emergency department. J Appl Lab Med. 2021;6(6):1607–10.

    Article  PubMed  Google Scholar 

  33. Leisman DE, Doerfler ME, Schneider SM, Masick KD, D’Amore JA, D’Angelo JK. Predictors, prevalence, and outcomes of early crystalloid responsiveness among initially hypotensive patients with sepsis and septic shock. Crit Care Med. 2018;46(2):189–98.

    Article  PubMed  Google Scholar 

  34. Monnet X, Marik PE, Teboul J-L. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6(1):111.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Blehar DJ, Glazier S, Gaspari RJ. Correlation of corrected flow time in the carotid artery with changes in intravascular volume status. J Crit Care. 2014;29(4):486–8.

    Article  PubMed  Google Scholar 

  36. Chebl RB, Wuhantu J, Kiblawi S, Dagher GA, Zgheib H, Bachir R, Carnell J. Corrected carotid flow time and passive leg raise as a measure of volume status. Am J Emerg Med. 2019;37(8):1460–5.

    Article  PubMed  Google Scholar 

  37. Kimura A, Suehiro K, Juri T, Tanaka K, Mori T. Changes in corrected carotid flow time induced by recruitment maneuver predict fluid responsiveness in patients undergoing general anesthesia. J Clin Monit Comput. 2021. https://doi.org/10.1007/s10877-021-00736-7.

    Article  PubMed  Google Scholar 

  38. Kim D-H, Shin S, Kim N, Choi T, Choi S, Choi Y. Carotid ultrasound measurements for assessing fluid responsiveness in spontaneously breathing patients: corrected flow time and respirophasic variation in blood flow peak velocity. Br J Anaesth. 2018;121(3):541–9.

    Article  PubMed  Google Scholar 

  39. Hossein-Nejad H, Mohammadinejad P, Lessan-Pezeshki M, Davarani SS, Banaie M. Carotid artery corrected flow time measurement via bedside ultrasonography in monitoring volume status. J Crit Care. 2015;30(6):1199–203.

    Article  PubMed  Google Scholar 

  40. Maitra S, Baidya DK, Anand RK, Subramanium R, Bhattacharjee S. Carotid artery corrected flow time and respiratory variations of peak blood flow velocity for prediction of hypotension after induction of general anesthesia in adult patients undergoing elective surgery: a prospective observational study. J Ultrasound Med. 2020;39(4):721–30.

    Article  PubMed  Google Scholar 

  41. Jung S, Kim J, Na S, Nam WS, Kim D-H. Ability of carotid corrected flow time to predict fluid responsiveness in patients mechanically ventilated using low tidal volume after surgery. J Clin Med. 2021;10(12):2676.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  42. Kim HJ, Choi YS, Kim SH, Lee W, Kwon JY, Kim DH. Predictability of preoperative carotid artery-corrected flow time for hypotension after spinal anaesthesia in patients undergoing caesarean section: a prospective observational study. Eur J Anaesthesiol. 2021;38(4):394–401.

    Article  PubMed  Google Scholar 

  43. Karadadaş S, Çorbacıoğlu ŞK, Çevik Y, Dağar S, Emektar E. Assessment of the carotid artery Doppler flow time in patients with acute upper gastrointestinal bleeding. Turk J Emerg Med. 2020;20(1):35.

    Article  PubMed  PubMed Central  Google Scholar 

  44. Jalil B, Thompson P, Cavallazzi R, Marik P, Mann J, El Kersh K, Guardiola J, Saad M. Comparing changes in carotid flow time and stroke volume induced by passive leg raising. Am J Med Sci. 2017. https://doi.org/10.1016/j.amjms.2017.09.006.

    Article  PubMed  Google Scholar 

  45. Beier L, Davis J, Esener D, Grant C, Fields JM. Carotid ultrasound to predict fluid responsiveness: a systematic review. J Ultrasound Med. 2020;39(10):1965–76.

    Article  PubMed  Google Scholar 

  46. Abbasi A, Azab N, Nayeemuddin M, Schick A, Lopardo T, Phillips GS, Merchant RC, Levy MM, Blaivas M, Corl KA. Change in carotid blood flow and carotid corrected flow time assessed by novice sonologists fails to determine fluid responsiveness in spontaneously breathing intensive care unit patients. Ultrasound Med Biol. 2020. https://doi.org/10.1016/j.ultrasmedbio.2020.07.001.

    Article  PubMed  PubMed Central  Google Scholar 

  47. Kenny J-ÉS, Barjaktarevic I, Eibl AM, Parrotta M. The feasibility of a novel, wearable Doppler ultrasound to track stroke volume change in a healthy adult. J Emerg Crit Care Med. 2020;4:17.

    Article  Google Scholar 

  48. Kenny JS, Barjaktarevic I, Eibl AM, Parrotta M, Long BF, Elfarnawany M, Eibl JK. Temporal concordance between pulse contour analysis, bioreactance and carotid Doppler during rapid preload changes. PLoS ONE. 2022;17(3): e0265711.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  49. Malbrain ML, Regenmortel N, Saugel B, Tavernier B, Gaal P-J, Joannes-Boyau O, Teboul J-L, Rice TW, Mythen M, Monnet X. Principles of fluid management and stewardship in septic shock: it is time to consider the four D’s and the four phases of fluid therapy. Ann Intensive Care. 2018;8(1):66.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

None applicable.

Funding

No specific funding supported this work.

Author information

Authors and Affiliations

Authors

Contributions

JESK—conception, primary drafting, analysis, critical revisions; SOG—analysis, patient enrollment, critical revisions; DJ—patient enrollment, analysis, critical revisions; ZY—analysis, critical revisions; LMH—patient enrollment, analysis, critical revisions, ME—analysis, critical revisions; JKE—conception, analysis, critical revisions; AJ—patient enrollment, analysis, critical revisions; AJB—patient enrollment, analysis, critical revisions; VCL—patient enrollment, analysis, critical revisions; BOK—patient enrollment, analysis, critical revisions. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Jon-Émile S. Kenny.

Ethics declarations

Ethics approval and consent to participate

Written and informed consent was obtained for all patients and the study was approved by the Peoria Institutional Review Board (# 1697834-5). The study was performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments.

Consent for publication

Written and informed consent was obtained for both patients for publication of this report and accompanying images.

Competing interests

JESK, SOG, DJ, ZY, LMH, ME, JKE work for Flosonics Medical, the start-up building the wearable Doppler ultrasound. AJ, AJB, VCL, BOK declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kenny, JÉ.S., Gibbs, S.O., Johnston, D. et al. The time cost of physiologically ineffective intravenous fluids in the emergency department: an observational pilot study employing wearable Doppler ultrasound. j intensive care 11, 7 (2023). https://doi.org/10.1186/s40560-023-00655-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40560-023-00655-6

Keywords