Skip to main content

Table 2 Performance of Q-CRT in predicting sepsis

From: Quantitative capillary refill time predicts sepsis in patients with suspected infection in the emergency department: an observational study

  AUC (95% CI) Sensitivity Specificity Difference between areas (95% CI) P value
Q-CRT 0.741 (0.627–0.835) 58.33 81.48
qSOFA 0.833 (0.729–0.909) 66.67 100 0.0926 (−0.0384–0.224) 0.1661
SIRS 0.61 (0.490–0.721) 81.25 40.74 0.131 (−0.0118–0.273) 0.0722
Lactate 0.769 (0.658–0.859) 72.92 81.48 0.0285 (− 0.119–0.176) 0.7036
  1. AUC area under the ROC curve, CI confidence interval, Q-CRT quantitative capillary refill time, qSOFA quick sequential organ failure assessment, SIRS systemic inflammatory response syndrome