Skip to main content

Table 3 Hemodynamic characteristics of sinus beats prior to ectopy and the post-ectopic beat for fluid non-responders and fluid responders

From: Extrasystoles for fluid responsiveness prediction in critically ill patients

 

Non-responders

Responders

p value

Baseline SBP (mmHg)

116 (21)

125 (35)

0.46

Post-ectopic SBP change (mmHg)

− 0.1 (5.6)

5.9 (6.6)

0.04

Baseline PEP (ms)

212 (39)

212 (34)

0.99

Post-ectopic PEP change (ms)

4.0 (5.3)

7.5 (2.9)

0.14

Baseline PP (mmHg)

58 (21)

65 (22)

0.51

Post-ectopic PP change (mmHg)

4.0 (6.7)

10.6 (7.0)

0.05

Baseline dP/dt (ms)

0.88 (0.47)

0.94 (0.39)

0.77

Post-ectopic dP/dt change (mmHg/ms)

0.08 (0.11)

0.16 (0.08)

0.10

  1. SBP systolic blood pressure, PEP pre-ejection period, PP pulse pressure